Datasheet| Type of measurement | TRMS AC |
| W max. | 600 kW |
| AAC max. | 600 AAC |
| Accuracy, current, AC | ±1.5 %+ 5 digits |
| VAC max. | 1000 VAC |
| VDC max. | 1000 VDC |
| Max. conductor ? | 37 mm |
| Total power factor | cos φ-1.00...+1.00 |
| THD%-F | 0.1...100 % |
| Hz max. | 10 kHz |
| Ohm max. | 100 kOhm |
| F max. | 4000 μF |
| Safety to EN61010 |
CAT IV 600 V
CAT III 1000 V |
| W resolution | 10 W |
| AAC resolution | 10 mA |
| VAC resolution | 0.01 V |
| VDC resolution | 0.01 V |
| Hz resolution | 0.01 Hz |
| Ohm resolution | 0.1 Ohm |
| F resolution | 0.001 μF |
| Bandwidth AAC | 0.4 kHz |
| Display | LCD, 9999 measurement points, with analogue bar display |
| Instrument functions |
Analogue bargraph
Backlight Flashlight Low-pass filter Non-contact voltage detection |
| Measuring function |
Continuity tester
Diode tester Hold Inrush Min./max. value Peak Hold |
| Dimensions L x W x H | 239 x 88 x 51 mm |
| Weight | 380 g |
| Electrical supply | 1 x 6LR61/9V |
| Description | Clamp Meter 600 AAC with Power Measurement |