Datasheet| Type of measurement | TRMS AC+DC |
| Digits | 1200000 |
| Bandwidth VAC | 300 kHz |
| Bandwidth AAC | 5 kHz |
| VAC max. | 600 VAC |
| VAC resolution | 0.1 μV |
| VDC max. | 600 VDC |
| VDC resolution | 0.1 μV |
| ADC max. | 1 ADC |
| ADC resolution | 0.0001 μA |
| AAC max. | 1 AAC |
| AAC resolution | 0.0001 μA |
| Ohm max. | 10 MOhm |
| Ohm resolution | 0.1 mOhm |
| Hz max. | 100 kHz |
| Hz resolution | 0.00001 Hz |
| °C measurement range | -270...+1372 °C |
| °C resolution | 0.01 °C |
| Sensor type/thermocouples |
PT100
PT1000 J K |
| Measuring function |
Data logger
Diode tester |
| Instrument functions | Frequency counter |
| Interfaces |
RS232
USB IEEE-488 (Optional) |
| Measuring error, DC volt | 0.003% |
| Measuring error, AC volt | 0.8% |
| Measuring error, DC ampere | 0.02% |
| Measuring error, AC ampere | 0.2% |
| Measuring error, resistance | 0.005...0.5% |
| Electrical supply |
115 VAC
230 VAC |
| Dimensions L x W x H | 365 x 285 x 75 mm |
| Weight | 3 kg |
| Description | Bench multimeter |
| Design | Bench |
| Delivery with |
Digital cable
Manual Power cable Test lead |